Choose the shape
Choose a straight run, L, U or rectangular perimeter. Measure each section between the outer post centres.
Plan a panel fence, position gates and see the panels and posts update immediately. The drawing and material list use the same dimensions.
Check the highlighted fields.
Cut width = centre spacing − (installation spacing − full panel width). Half-millimetre cuts are retained. Check the cutting and fixing details for your product.
One purchased panel per bay; offcuts are not reused. One cap is counted for every post.
Choose a straight run, L, U or rectangular perimeter. Measure each section between the outer post centres.
Enter panel width and post centres from the installation manual. These are two different measurements.
Add gates or pedestrian gates with their clear width and position. Each opening appears in the drawing.
Review both views, the post totals and cutting list. Print a one-page summary or save it as PDF.
The width of the product itself. Cuts must retain suitable fixing points allowed by the manufacturer.
The distance between adjacent post centres. Posts and brackets can make this different from the panel width.
The gap between the inside faces of the gate posts. With equal posts, centre spacing is the clear gap plus one post width.
Each continuous fence run between end, corner or gate posts is calculated separately. Subtracting all gates from a total perimeter and rounding only once can give the wrong panel count.
Number of bays⌈ continuous run length ÷ installation spacing ⌉
Gate post centre spacingclear opening + one gate post width
Fixing connectionsconnection positions × fixings per position
A straight fence without openings needs N + 1 posts for N bays. A closed perimeter shares its first and last post. A corner post serves two sections but is bought once. A shared corner/gate post is listed as a gate post.
If the last cut is under 20% of full panel width and at least two bays exist in that run, only the last two bays are balanced. For a 25 m section with a 4.40 m opening at the start, 80 mm gate posts and a 2500/2530 mm system, this gives seven full panels and two 1375 mm cuts instead of a 250 mm final cut. The 20% threshold is a planning choice; cutting suitability still depends on the product.
A 25.30 m section with 2530 mm post centres uses 10 full panels and 11 posts. With 2500 mm panels, their combined width is 25 m; the centre-to-centre fence length is 25.30 m.
For level sites, one panel height and right-angle corners. Each section: 0.5–200 m; full panel width: 500–3500 mm; height: 500–2500 mm; post centres: 500–4000 mm and between panel width and width + 500 mm. Gate clear width: 0.6–8 m; pedestrian gate: 0.6–2 m; gate post width: 40–200 mm. Maximum 12 openings and 1000 panels, minimum cut width 100 mm. Enter dimensions to 1 mm and prices to 0.01 currency units. These are tool limits, not construction rules. Foundations, slopes, sliding-gate counterweights and structural post sizing are excluded. Separate adjacent fence and gate posts at the same connection are not modelled.
The 2500/2530 mm preset comes from the Betafence Nylofor / Twilfix installation manual; fixing counts come from its post data. This is one product system, not a national standard. Check your own supplier’s spacing, post specification and fixing method. No market prices or permit rules are assumed.
Nylofor / Twilfix installation manual (PDF) · Manufacturer’s post and fixing data
All bays, including those beside gate posts, use the same allowance between panel width and post centres. If gate connections need a different allowance, adjust cut dimensions using the actual connection drawing.
Divide each continuous run by the system’s installation spacing and round up. A straight run without openings needs one more post than panels. Shared corner and gate posts are counted once.
Choose a shared clamp or separate panel ends. Shared clamps are not duplicated on straight intermediate posts; both directions count at corners. Enter the manufacturer’s fixing count for your system and height.
No. Post centres depend on the post and fixing system. The Betafence Nylofor / Twilfix example uses 2500 mm panels and 2530 mm centres. For another system, use its actual instructions.
Section length is between the outer post centres. Gate position runs from the section’s first post centre to the first gate post centre. Clear gate width excludes the posts; one post width is added to obtain their centre spacing.
Each opening splits the fence into separate runs, rounded individually. Opening supports are gate posts and shared supports are not duplicated. Gate mechanisms and sliding-gate counterweights are excluded.
No. Each bay uses a separate purchased panel. The cutting list gives required blank widths. Check permitted cuts, remaining mesh and fixing points with the manufacturer.
Below 20% of full width, the last two bays are balanced if the run has at least two panels. Other panels stay full. This is a planning rule, not a product minimum. A single short bay must still provide at least a 100 mm blank in this tool.
Sections are 0.5–200 m, panel widths 500–3500 mm and heights 500–2500 mm. Gate openings are 0.6–8 m; pedestrian gates 0.6–2 m. Up to 12 openings and 1000 panels are supported. These are tool limits, not installation standards.
Yes. Open Prices and enter your own rates. Fields start blank and the total includes only entered, applicable items. Explicit zero is included. Missing rates and excluded work are listed separately.
The model covers horizontal runs on level ground. Sloping or stepped installation, retaining walls and height changes are excluded. This is a centre-to-centre layout, not a land survey.
Fence dimensions and prices are calculated in your browser. This tool does not upload or retain them after the page is closed. You can print or save the summary as PDF on your device.