01 Fence shape

m

Measure between the centres of the outermost posts.

02 Panels and installation

Dimension preset
Manufacturer example: 2500 mm panel, 2530 mm post centres, 1530 mm height. Enter your product’s dimensions for another system.
mm
mm
mm

Full panels are kept wherever possible. If the last cut is narrower than 20% of a full panel, the final two bays are balanced. This is a layout rule, not a manufacturer’s limit.

Gates and pedestrian gates

Position is measured from the first post centre to the first gate post centre. Arrows show the measuring direction.

Fixings and spare panels
A shared clamp holds both adjacent panels on a straight intermediate post. Both directions are counted at corners.
each
4 is the Nylofor / Twilfix preset for a 1530 mm panel. Use the manufacturer’s count for another height or system.
%
The percentage adds purchased panels only, not posts or fixings.
Prices optional

Enter only the prices you want to include. Blank prices are excluded. Enter tax-inclusive amounts in the displayed currency; no currency conversion is applied.

£/each
£/each
£/each
£/each
£/each
£/each
£/m
YOUR FENCE PLAN

From the first post to the last

Full panel Cut panel Post

Sections and panel cutting list

Cut width = centre spacing − (installation spacing − full panel width). Half-millimetre cuts are retained. Check the cutting and fixing details for your product.

Material list

One purchased panel per bay; offcuts are not reused. One cap is counted for every post.

How to use the fence calculator

01

Choose the shape

Choose a straight run, L, U or rectangular perimeter. Measure each section between the outer post centres.

02

Check the system dimensions

Enter panel width and post centres from the installation manual. These are two different measurements.

03

Position the gates

Add gates or pedestrian gates with their clear width and position. Each opening appears in the drawing.

04

Use the material list

Review both views, the post totals and cutting list. Print a one-page summary or save it as PDF.

Three measurements to keep separate

Panel width

The width of the product itself. Cuts must retain suitable fixing points allowed by the manufacturer.

Installation spacing

The distance between adjacent post centres. Posts and brackets can make this different from the panel width.

Clear gate width

The gap between the inside faces of the gate posts. With equal posts, centre spacing is the clear gap plus one post width.

How panels and posts are calculated

Each continuous fence run between end, corner or gate posts is calculated separately. Subtracting all gates from a total perimeter and rounding only once can give the wrong panel count.

Number of bays⌈ continuous run length ÷ installation spacing ⌉

Gate post centre spacingclear opening + one gate post width

Fixing connectionsconnection positions × fixings per position

Why the fence shape changes the post count

A straight fence without openings needs N + 1 posts for N bays. A closed perimeter shares its first and last post. A corner post serves two sections but is bought once. A shared corner/gate post is listed as a gate post.

Avoiding a very narrow final panel

If the last cut is under 20% of full panel width and at least two bays exist in that run, only the last two bays are balanced. For a 25 m section with a 4.40 m opening at the start, 80 mm gate posts and a 2500/2530 mm system, this gives seven full panels and two 1375 mm cuts instead of a 250 mm final cut. The 20% threshold is a planning choice; cutting suitability still depends on the product.

Example without gates

A 25.30 m section with 2530 mm post centres uses 10 full panels and 11 posts. With 2500 mm panels, their combined width is 25 m; the centre-to-centre fence length is 25.30 m.

Model and input limits

For level sites, one panel height and right-angle corners. Each section: 0.5–200 m; full panel width: 500–3500 mm; height: 500–2500 mm; post centres: 500–4000 mm and between panel width and width + 500 mm. Gate clear width: 0.6–8 m; pedestrian gate: 0.6–2 m; gate post width: 40–200 mm. Maximum 12 openings and 1000 panels, minimum cut width 100 mm. Enter dimensions to 1 mm and prices to 0.01 currency units. These are tool limits, not construction rules. Foundations, slopes, sliding-gate counterweights and structural post sizing are excluded. Separate adjacent fence and gate posts at the same connection are not modelled.

Manufacturer data and assumptions

The 2500/2530 mm preset comes from the Betafence Nylofor / Twilfix installation manual; fixing counts come from its post data. This is one product system, not a national standard. Check your own supplier’s spacing, post specification and fixing method. No market prices or permit rules are assumed.

Nylofor / Twilfix installation manual (PDF) · Manufacturer’s post and fixing data

All bays, including those beside gate posts, use the same allowance between panel width and post centres. If gate connections need a different allowance, adjust cut dimensions using the actual connection drawing.

Fence calculator questions

How many panels and posts do I need?

Divide each continuous run by the system’s installation spacing and round up. A straight run without openings needs one more post than panels. Shared corner and gate posts are counted once.

How are the fixings counted?

Choose a shared clamp or separate panel ends. Shared clamps are not duplicated on straight intermediate posts; both directions count at corners. Enter the manufacturer’s fixing count for your system and height.

Does a 2.5 m panel mean 2.5 m post centres?

No. Post centres depend on the post and fixing system. The Betafence Nylofor / Twilfix example uses 2500 mm panels and 2530 mm centres. For another system, use its actual instructions.

Where do I measure the section and gate position?

Section length is between the outer post centres. Gate position runs from the section’s first post centre to the first gate post centre. Clear gate width excludes the posts; one post width is added to obtain their centre spacing.

How do gates affect the material list?

Each opening splits the fence into separate runs, rounded individually. Opening supports are gate posts and shared supports are not duplicated. Gate mechanisms and sliding-gate counterweights are excluded.

Are panel offcuts reused?

No. Each bay uses a separate purchased panel. The cutting list gives required blank widths. Check permitted cuts, remaining mesh and fixing points with the manufacturer.

What happens if the final panel is too narrow?

Below 20% of full width, the last two bays are balanced if the run has at least two panels. Other panels stay full. This is a planning rule, not a product minimum. A single short bay must still provide at least a 100 mm blank in this tool.

What are the input limits?

Sections are 0.5–200 m, panel widths 500–3500 mm and heights 500–2500 mm. Gate openings are 0.6–8 m; pedestrian gates 0.6–2 m. Up to 12 openings and 1000 panels are supported. These are tool limits, not installation standards.

Can I calculate the fence cost?

Yes. Open Prices and enter your own rates. Fields start blank and the total includes only entered, applicable items. Explicit zero is included. Missing rates and excluded work are listed separately.

Can I use this for a slope or uneven ground?

The model covers horizontal runs on level ground. Sloping or stepped installation, retaining walls and height changes are excluded. This is a centre-to-centre layout, not a land survey.

Are my dimensions sent to a server?

Fence dimensions and prices are calculated in your browser. This tool does not upload or retain them after the page is closed. You can print or save the summary as PDF on your device.