Wall dimensions
Enter the finished wall size in millimetres.
Plan plasterboard sheets, metal studs, tracks and fixings for one or two layers.
For straight, non-loadbearing internal partitions. For tall, curved, fire-rated or other specialist walls, consult a qualified professional and the complete manufacturer’s system specification.
Enter the finished wall size in millimetres.
Profile depth, stud centres and stock lengths.
Use compatible C studs and U channels from one system; actual channel width can differ from stud depth.
Choose layers and the sheets you will buy.
The drawing shows one face; buying quantities include both faces if selected.
Measure the wall, choose compatible frame and sheet sizes, then review the layout and shopping list. Check your chosen system before ordering.
Enter finished width and height, then choose one or both boarded faces. Add a door only if its opening and position are known.
Choose a compatible C-stud and U-channel system, stud centres and stock lengths that your merchant actually sells.
Set the sheet width, length, thickness and one or two layers per face. Short sheets may need supported horizontal joints.
Switch between frame and board views. Check the cutting plan, optional spare and system details before ordering.
C studs form the uprights, while U channels form the floor and ceiling tracks. Their nominal dimensions need not be identical: buy sections specified together as a complete system.
A door opening may require reinforced jamb studs and matching brackets. The correct detail depends on door weight and the system supplier, not just the wall width.
On a two-layer lining, the outer boards start on different supported studs so their vertical joints do not align with the inner layer. Joints on the opposite face should also be offset.
Fill inner-layer joints where the manufacturer requires it before fixing the outer layer. Finish exposed joints with compatible compound and tape.
The cutting plan packs stud and channel sections into the selected stock lengths and reuses suitable offcuts. Board offcuts can be used across layers and faces when their dimensions fit.
The bold sheet count is the planned minimum. A spare appears separately only when the usable cutting margin is tight; door cut-outs are not assumed reusable.
This estimate does not establish a fire or acoustic rating, permissible wall height or structural support. Tall, wet-area, heavily loaded or separating walls need the manufacturer’s complete tested system and professional review.
Plan additional backing for heavy cabinets, sanitaryware or screens. Those supports are not included in this material list.
Indicative material estimate, not a tested partition design. Verify all details with the system manufacturer.